Media Component Power Supply Module Failure Alarm

This alarm is applicable only to the Media Transcoding Cluster feature (Mediant 9000 and Mediant VE).

acMtcePsuFailureAlarm

Alarm

acMtcePsuFailureAlarm

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.120

Description

The alarm is sent upon a failure in the Power Supply module of the Media Component (MC type).

Default Severity

Minor

Alarm Source

…./MTCE#1/powerSupply#1

Event Type

equipmentAlarm

Probable Cause

powerProblem

Severity

Condition

Alarm Text

Corrective Action

Minor

Failure in Power Supply module of Media Component

"MTCE power supply unit fault"

1. Check if the Power Supply module is inserted in the chassis.
2. If it was removed from the chassis, re-insert it.
3. If the Power Supply module is inserted in the chassis and the alarm is still sent, send a Return Merchandise Authorization (RMA) request to AudioCodes.

Cleared

Power Supply module status returns to normal

-

-